Qualité Industrielle |
Qualité Durcie |
Qualité Militarisée |
Température de fonctionnement |
0 to +50°C |
0 to +50°C |
‐10 to +50°C
(MIL‐STD‐810G, Method 502.5, Procedure
2, 4 hours,
MIL‐STD‐810G, Method 501.5, Procedure
2, 12 hours)
|
Température de stockage |
‐20 to +70°C |
‐20 to +70°C |
‐40 to +75°C
(MIL‐STD‐810G, Method 501.5, Procedure
1, 4 hours, MIL‐STD‐810G, Method 501.5, Procedure
1, 4 hours)
|
Fonctionnement en fonction de l’humidité |
5 – 90% RH, non‐condensing at 35°C |
5 – 90% RH, non‐condensing at 35°C |
95% RH at +40°C
(EN60068‐2‐3, test Cab: 40°C (+/‐2°C),
95% RH, 10 days)
|
Stockage de l’humidité |
5 ‐ 95% @ 45°C |
5 ‐ 95% @ 45°C |
95% RH at 25 to 55°C
( EN60068‐2‐30, test Db variant 2: 25°C
(+/‐ 3°C) to 55°C (+/‐ 2°C), 95% (+/‐4%)
RH, 6 cycles, 24 hours per cycle)
|
Pression (altitude) |
650 to 1100 hPa |
650 to 1100 hPa |
550 to 1100 hPa |
Chocs |
15g, 11ms 6 axis (With SSD) |
20g, 11ms 6 axis (With SSD) |
20g, 18ms 6 axis (With SSD)
(MIL‐STD‐810F, method 516.5, procedureI)
|
Fonctionnement en vibrations |
5‐100 Hz 0.8g |
5 ‐ 300 Hz @ 0.8g |
5 ‐ 500 Hz @ 0.8g |
Transport des vibrations (aléatoire) |
5 ‐ 500 Hz @ 0.8g |
5 ‐ 500 Hz @ 1g |
5‐2000Hz @ 1g
(MIL‐STD‐810F method 514‐5 procedure 1)
5 ‐ 500 Hz @ 2g
(MIL‐STD‐167‐1A)
|
Accélération – atterrissage d’urgence |
5g |
5g |
8g |
Accélération – transport |
3g |
3g |
4.5g |
EMC |
CE Mark Class B
(EN 61000‐6‐2, EN55022, EN 55024) |
CE Mark Class B
(EN 61000‐6‐2, EN55022, EN 55024) |
CE Mark Class B
(EN 61000‐6‐2, EN55022, EN 55024) |
Sécurité |
EN 60950‐1 |
EN 60950‐1 |
EN 60950‐1 |
Immunité aux surtensions |
EN 61000‐4‐5
STANAG 1008 |
EN 61000‐4‐5
STANAG 1008 |
EN 61000‐4‐5
STANAG 1008 |
Susceptibilité aux radiations |
– |
– |
NRS01, NRS02, NRS04 tests of AECTP‐500 |
Émissions de radiations |
– |
– |
NRE01, NRE02 tests of AECTP‐500 |
Susceptibilité par conduction |
– |
– |
NCS01, NCS07, NCS08, NCS09, NCS11,
NCS12, NCS13 tests of AECTP‐500 |
Émissions par conduction |
– |
– |
NCE01, NCE02, NCE04, NCE05 tests of
AECTP‐500 |
Continuité de masse – Boîtier externe |
10mOhm @ 1A |
5mOhm @ 5A |
5mOhm @ 10A |
Continuité de masse – Boîtier interne |
– |
– |
10mOhm @ 10A |
Bruit à pleine vitesse |
IW2U5 & IS2U51S: 50 dB(A)
IS2U5 : 70 dB(A) |
RW2U5 & RS2U51S: 50 dB(A)
RS2U5 : 70 dB(A) |
MW2U5 & MS2U51S: 50 dB(A)
MS2U5 : 70 dB(A) |